Alternative NSN: 5940-01-122-7358 |
Item Name: Terminal Board |
CAGE Code : 13150 , 71785 , 83330 , 26405 , 08783 |
NIIN: 011227358 |
FSG: 59 Electrical and Electronic Equipment Components |
FSC Name: 5940 Lugs Terminals and Terminal Strips |
NCB Code: USA (01) |
Manufacturers: axsys technologies inc , cinch connectors inc , dialight corporation , marathon special products , raytheon company |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
10106 | axsys technologies inc | terminal board | Avl | |
351-27-06-001 | cinch connectors inc | terminal board | Avl | |
6-172-3 4W | cinch connectors inc | terminal board | Avl | |
410-JJ-3 4ST-6 | dialight corporation | terminal board | Avl | |
410-JJ-3 4ST-06 | marathon special products | terminal board | Avl | |
37675718-003 | raytheon company | terminal board | Avl |
MRC | Criteria | Characteristic |
---|---|---|
AAMA | MOUNTING HOLE DIAMETER | 0.125 INCHES |
AAPB | DIELECTRIC WITHSTANDING VOLTAGE IN VOLTS | 1000.0 |
AAQL | BODY STYLE | BARRIER TYPE |
ABCS | TERMINAL ROW QUANTITY | 2 |
ABCT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.250 INCHES |
ABCU | DISTANCE BETWEEN TERMINAL ROW CENTERS | 0.250 INCHES |
ABCX | BOARD CONSTRUCTION | SOLID CONSTRUCTION |
ABDU | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES |
ABDV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.250 INCHES |
ABDW | DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE | 0.188 INCHES |
ABDX | DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY | 0.125 INCHES |
ABGN | BOARD OVERALL LENGTH | 2.000 INCHES |
ABGP | BOARD OVERALL WIDTH | 0.625 INCHES |
ABGQ | BOARD OVERALL HEIGHT | 0.328 INCHES |
ABGR | BOARD HEIGHT EXCLUDING TERMINALS | 0.328 INCHES |
ABGS | BASE THICKNESS | 0.218 INCHES |
AMPS | CURRENT RATING IN AMPS | 5.0 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
CQCZ | TERMINAL CONNECTING LINK QUANTITY | 6 SINGLE |
CRNL | NONFEEDTHRU TERMINAL TYPE | 163 SECOND |
CRNL | NONFEEDTHRU TERMINAL TYPE | 857 FIRST |
CSCR | TERMINAL CONNECTING LINK TYPE | 1 SINGLE |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 6 FIRST |
CSCS | NONFEEDTHRU TERMINAL QUANTITY | 6 SECOND |
CWLG | TERMINAL PATTERN ARRANGEMENT | MULTI-ROW |
CWLN | TERMINAL DESIGN | NONFEEDTHRU |
MATT | MATERIAL | COPPER ALLOY TERMINALS |
MATT | MATERIAL | PLASTIC PHENOLIC BOARD |
SFTT | SURFACE TREATMENT | NICKEL TERMINALS AND TIN TERMINALS |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.