Alternative NSN: 5950-01-168-5968 |
Item Name: Transformer Power |
CAGE Code : 16236 , 06RP6 , 02750 , 72149 |
NIIN: 011685968 |
FSG: 59 Electrical and Electronic Equipment Components |
FSC Name: 5950 Coils and Transformers |
NCB Code: USA (01) |
Manufacturers: dla land and maritime , drs consolidated controls inc , eaton aerospace ltd , electronic transformer corp |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
LO3329 | dla land and maritime | transformer power | Avl | |
115133 G1 | drs consolidated controls inc | transformer power | Avl | |
115133 G1 | eaton aerospace ltd | transformer power | Avl | |
115133 G1 | electronic transformer corp | transformer power | Avl |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 4.500 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 4.125 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED STUD SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CMLP | THREAD QUANTITY PER INCH | 20 SINGLE GROUP |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 3.18 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.5 AMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 164.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 164.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 365.5 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 37.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 125.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 41.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 41.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3329 |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 10 SOLDER STUD |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | REFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.