Alternative NSN: 6110-01-167-1499 |
Item Name: Starter Motor |
CAGE Code : 27192 |
NIIN: 011671499 |
FSG: 61 Electric Wire and Power and Distribution Equipment |
FSC Name: 6110 Electrical Control Equipment |
NCB Code: USA (01) |
Manufacturers: drs power and control technologies |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
6962ED1944A3 | drs power and control technologies | starter motor | Avl |
MRC | Criteria | Characteristic |
---|---|---|
ABBB | SPEED ADJUSTMENTS | 0 TO FULL SPEED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
ABHP | OVERALL LENGTH | 28.125 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 11.500 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 22.108 INCHES NOMINAL |
ACYN | AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
AFLW | ACTUATION METHOD | MAGNETIC |
AGLD | PERFORMANCE TYPE | MANUAL |
AGUE | FUSE ACCOMMODATION QUANTITY | 5 |
AJXE | SIZE DESIGNATOR | 5 |
AKPS | DUTY CYCLE | CONTINUOUS |
ALGC | MOUNTING CONFIGURATION | SIX 17/32 IN. DIA HOLES; RECTANGULAR PATTERN; TWO ROWS 3 EA; 26 IN. CL TO CL ROWS; HOLES SPACED 8-1/2 IN. AND 10-1/2 IN. LEFT AND RIGHT OF CENTER HOLE |
ANCN | OPERATING VOLTAGE CHARACTERISTIC | FULL |
ANCY | HORSEPOWER RATING | 200.000 |
ANDE | ACTUATOR VOLTAGE | 440.0 AC |
ANDG | FUSE CURRENT RATING IN AMPS | 10.0 |
ANDW | LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |
ANDX | AMBIENT TEMP | 50.0 DEG CELSIUS |
ANPZ | INCLOSURE FEATURE | DRIPPROOF |
ANQC | NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
AQZF | CONTROL TYPE | LOCAL OR REMOTE |
CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
FAAZ | PHASE | THREE |
FREQ | FREQUENCY IN HERTZ | 60.0 |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.