| Alternative NSN: 5905-00-542-9657 |
| Item Name: Resistor Fixed Wire |
| CAGE Code : 63743 |
| NIIN: 005429657 |
| FSC Name: 5905 Resistors |
| NCB Code: USA (00) |
| Manufacturers: ward leonard electric company inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 6W201TVIT200HMT2T8T8T2 | ward leonard electric company inc | resistor fixed wire | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPP | ELECTRICAL RESISTANCE | 20.000 OHMS20.000 OHMS20.000 OHMS20.000 OHMS20.000 OHMS |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000-10.000 TO 10.000 |
| AAPR | FIXED TAP QUANTITY | 33333 |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 350.0350.0350.0350.0350.0 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHEDNOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 0.562 INCHES NOMINAL0.562 INCHES NOMINAL0.562 INCHES NOMINAL |
| ABPM | BODY DIAMETER | 0.938 INCHES NOMINAL0.938 INCHES NOMINAL0.938 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL6.000 INCHES NOMINAL6.000 INCHES NOMINAL |
| AEFB | POWER DISSIPATION RATING IN WATTS | 90.000 FREE AIR90.000 FREE AIR90.000 FREE AIR |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | 50.0 DEG CELSIUS50.0 DEG CELSIUS50.0 DEG CELSIUS |
| AFWW | TERMINAL WIDTH | 0.438 INCHES NOMINAL0.438 INCHES NOMINAL0.438 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | ENCAPSULATEDENCAPSULATEDENCAPSULATED |
| CQFD | SECTION NOMINAL RESISTANCE | 2.000 OHMS 1ST SECTIONUNABLE TO DECODE |
| CQFD | SECTION NOMINAL RESISTANCE | 2.000 OHMS 4TH SECTIONUNABLE TO DECODE |
| CQFD | SECTION NOMINAL RESISTANCE | 8.000 OHMS 2ND SECTIONUNABLE TO DECODE |
| CQFD | SECTION NOMINAL RESISTANCE | 8.000 OHMS 3RD SECTIONUNABLE TO DECODE |
| CQFK | FIXED TAP TERMINAL TYPE | TAB W/SCREWTAB W/SCREW |
| CSCF | TERMINAL TYPE | TAB W/SCREWTAB W/SCREW |
| STYL | STYLE DESIGNATOR | RADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH ENDRADIAL TERMINAL EACH END |
| TEST | TEST DATA DOCUMENT | 81349-MILR15109B SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
| ZZZT | NONDEFINITIVE SPEC/STD DATA | IW FORMIW FORMIW FORMIW FORM |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.
Request for Quote