| Alternative NSN: 5910-00-430-5820 |
| Item Name: Capacitor Fixed Cer |
| CAGE Code : 60705 , 28480 , 1LQK8 , 91418 |
| NIIN: 004305820 |
| FSC Name: 5910 Capacitors |
| NCB Code: USA (00) |
| Manufacturers: ceramite corp , hewlett-packard company , keysight technologies inc , radio materials corp |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 562CZ5UKE101AH253ZX | ceramite corp | capacitor fixed cer | Avl | |
| 0160-3208 | hewlett-packard company | capacitor fixed cer | Avl | |
| 0160-3208 | keysight technologies inc | capacitor fixed cer | Avl | |
| TA-025P80M20PCT0KLPI | radio materials corp | capacitor fixed cer | Avl | |
| TA0-025UF100V | radio materials corp | capacitor fixed cer | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | W/O MTG FACILITIES,RADIAL TERMINALS |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| ABPM | BODY DIAMETER | 0.500 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 0.125 INCHES MAXIMUM |
| AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.375 INCHES NOMINAL |
| AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE S) |
| AGAV | END ITEM IDENTIFICATION | FORRESTAL CLASS CV SAFEGUARD CLASS ARS VIRGINIA CLASS CGN 41) OLIVER PERRY CLASS FFG SPRUANCE CLASS DD 963) AUSTIN SHIP CLASS LPD-4 AMPHIBIOUS TRANSPORT DOCKS WHIDBEY ISLAND CLASS LSD SUPPLY CLASS AOE TARAWA CLASS LHA NIMITZ CLAS |
| CQBQ | CAPACITANCE VALUE PER SECTION | 0.025 MICROFARADS SINGLE SECTION |
| CQFB | VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE | -82.0 TO 22.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION |
| CQJJ | NONDERATED OPERATING TEMP | 10.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
| CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 100.0 DC SINGLE SECTION |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| CRTP | TOLERANCE RANGE PER SECTION | -20.00 TO 80.00 PERCENT SINGLE SECTION |
| CWJK | CASE MATERIAL | PLASTIC |
| CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 7500.0 MEGOHMS |
| CWPN | POWER FACTOR AT REFERENCE TEMP IN PERCENT | 3.0000 |
| CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
| FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |