| Alternative NSN: 5925-00-738-7301 |
| Item Name: Circuit Breaker |
| CAGE Code : D9475 , D5589 , 94580 , D2692 , D9893 |
| NIIN: 007387301 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (00) |
| Manufacturers: bundesamt fuer wehrtechnik , feinmechanische werke mainz gmbh , honeywell international inc , krauss maffei wegmann gmbh and co , liebherr aerospace lindenberg gmbh |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 25704-281600-05-0 | bundesamt fuer wehrtechnik | circuit breaker | Avl | |
| 7387301 | feinmechanische werke mainz gmbh | circuit breaker | Avl | |
| 500396 | honeywell international inc | circuit breaker | Avl | |
| 25704-281600-05-0 | krauss maffei wegmann gmbh and co | circuit breaker | Avl | |
| 7387301 | liebherr aerospace lindenberg gmbh | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABMK | OVERALL WIDTH | 2.125 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 4000.0 DC SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
| ABHP | OVERALL LENGTH | 4.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.969 INCHES NOMINAL |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.500 INCHES NOMINAL |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 200.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 30.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRW | ACTUATOR FUNCTION | RESET |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 300.000 NOMINAL AT 125 PCT AND 40.000 NOMINAL AT 200 PCT AND 12.000 NOMINAL AT 300 PCT AND 15.000 NOMINAL AT 400 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |