| Alternative NSN: 5925-00-874-0952 |
| Item Name: Circuit Breaker |
| CAGE Code : 06402 , 33867 |
| NIIN: 008740952 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (00) |
| Manufacturers: oakland industries ltd , oceanetics inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 48-300-S-H | oakland industries ltd | circuit breaker | Avl | |
| 48-210SH | oakland industries ltd | circuit breaker | Avl | |
| 600645 | oceanetics inc | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ABTD | MOUNTING SLOT WIDTH | 0.190 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.820 INCHES NOMINAL |
| ADAT | BODY WIDTH | 3.150 INCHES NOMINAL |
| AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 60.0 AC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 20.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB W/SCREW |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.760 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.650 INCHES NOMINAL |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 380.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 140.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | AUTOMATIC |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH BUTTON |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 2 ALARM |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE AND INTERNAL AT POLE THREE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 10.000 MINIMUM AT 200 PCT AND 45.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 3.0 AC |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC |
| CWJK | CASE MATERIAL | PLASTIC |