| Alternative NSN: 5925-01-050-9030 |
| Item Name: Circuit Breaker |
| CAGE Code : 95105 , 56365 , 88434 |
| NIIN: 010509030 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: rockwell collins aerospace , schneider electric gmbh , square d company |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 214-0006-009 | rockwell collins aerospace | circuit breaker | Avl | |
| Q1350VH | schneider electric gmbh | circuit breaker | Avl | |
| Q1350VH | square d company | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| TTQY | Terminal Type And Quantity | 3 COMPRESSION |
| CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
| AFJN | Fragility Factor | MODERATELY RUGGED |
| BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 10000.0 AC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
| AJEC | Boss Height | 0.250 INCHES NOMINAL |
| AKPX | Pole Quantity | 3 |
| MRC | Decoded Requirement | Clear Text Reply |
| AXHR | Mounting Facility Type And Quantity | 6 TERMINAL |
| CPRQ | Reset Method | MANUAL |
| CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| CPRW | Actuator Function | TRIP-RESET |
| ADAT | Body Width | 2.230 INCHES NOMINAL |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| ADTV | Case Material | PLASTIC |
| TTQY | Terminal Type And Quantity | 3 CLIP AND |
| ADAQ | Body Length | 6.250 INCHES NOMINAL |
| ADAU | Body Height | 2.580 INCHES NOMINAL |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES NOMINAL |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
| APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 240.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
| CPRX | Actuator Position Designation | AT POLE TWO |
| CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT |