| Alternative NSN: 5925-01-256-3070 |
| Item Name: Circuit Breaker |
| CAGE Code : 08XT8 , 06402 , 00365 |
| NIIN: 012563070 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: hsmv corp , oakland industries ltd , tld ace corporation |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| F1R12 A82 1060 001 | hsmv corp | circuit breaker | Avl | |
| 41-3-S14-LN2-40A | oakland industries ltd | circuit breaker | Avl | |
| 1003990 | tld ace corporation | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ABXD | BUSHING LENGTH | 0.260 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.260 INCHES NOMINAL |
| ADAT | BODY WIDTH | 0.730 INCHES NOMINAL |
| ADTV | CASE MATERIAL | PLASTIC |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.900 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.520 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 40.0 AMPERES AC SINGLE LOCATION AND 40.0 AMPERES DC SINGLE LOCATION |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SINGLE LOCATION AND 1000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.438 INCHES |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 12.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 80.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND FUNGUS RESISTANT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 70.0 DEG FAHRENHEIT NOMINAL SINGLE LOCATION |
| FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
| PKWT | UNPACKAGED UNIT WEIGHT | 2.300 OUNCES |
| THSD | THREAD SERIES DESIGNATOR | UN |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |