| Alternative NSN: 5925-01-314-8128 |
| Item Name: Circuit Breaker |
| CAGE Code : 32856 , 6PW80 , 21810 |
| NIIN: 013148128 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: american circuit breaker corp , cbs nuclear services inc , challenger electrical equipment corp |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| XJL434300-50DEG | american circuit breaker corp | circuit breaker | Avl | |
| XJL434300 | cbs nuclear services inc | circuit breaker | Avl | |
| XJL434300-50DEG C | challenger electrical equipment corp | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.250 INCHES NOMINAL |
| CPRQ | RESET METHOD | MANUAL |
| CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| AKPX | POLE QUANTITY | 3 |
| ABHP | OVERALL LENGTH | 17.310 INCHES NOMINAL |
| APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
| ABKW | OVERALL HEIGHT | 5.190 INCHES NOMINAL |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 300.0 AMPERES AC ALL LOCATIONS |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 480.0 AC ALL LOCATIONS |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 150000.0 AC ALL LOCATIONS |
| AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
| CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | 2000.0 TO 3200.0 AC ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
| ADTV | CASE MATERIAL | PLASTIC |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| ABMK | OVERALL WIDTH | 8.250 INCHES NOMINAL |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |