Alternative NSN: 5925-01-351-0694 |
Item Name: Circuit Breaker |
CAGE Code : 076M6 , 0FW39 , 45152 , 81541 |
NIIN: 013510694 |
FSG: 59 Electrical and Electronic Equipment Components |
FSC Name: 5925 Circuit Breakers |
NCB Code: USA (01) |
Manufacturers: bae systems land and armaments l p , bae systems tactical vehicle systems lp , oshkosh corporation , sensata technologies inc |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
AP7-1-50-103 | bae systems land and armaments l p | circuit breaker | Avl | |
AP7-1-50-103 | bae systems tactical vehicle systems lp | circuit breaker | Avl | |
2GA433 | oshkosh corporation | circuit breaker | Avl | |
AP7-1-50-103 | sensata technologies inc | circuit breaker | Avl |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1 605 INCHES MAXIMUM |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 10 000 AMPERES DC SINGLE LOCATION |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CQJX | NOMINAL THREAD SIZE | 0 375 INCHES |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
ABXD | BUSHING LENGTH | 0 380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1 562 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0 625 INCHES MAXIMUM |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 500 0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNEF |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0 875 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING WPANEL SEAL |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115 0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0 200 MINIMUM AT 200 PCT AND 1 800 MAXIMUM AT 200 PCT SINGLE LOCATION |
AKPX | POLE QUANTITY | 1 |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 50 0 DC SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.
Request for Quote