| Alternative NSN: 5925-01-379-7451 |
| Item Name: Circuit Breaker |
| CAGE Code : 64959 , 06402 |
| NIIN: 013797451 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: american telephone and telegraph co , oakland industries ltd |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 405645821 | american telephone and telegraph co | circuit breaker | Avl | |
| 3120-F323-P7T1-R | oakland industries ltd | circuit breaker | Avl | |
| 12L-B4 | oakland industries ltd | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145.0 ALL LOCATIONS |
| AKPX | POLE QUANTITY | 2 |
| PKWT | III UNPACKAGED UNIT WEIGHT | 2.600 OUNCES |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 CLIP |
| AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
| ADTV | CASE MATERIAL | PLASTIC |
| ADAT | BODY WIDTH | 1.540 INCHES NOMINAL |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC AND 2.0 AMPERES DC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| FREQ | FREQUENCY IN HERTZ | 50.0 OR 60.0 ALL LOCATIONS |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.595 INCHES MINIMUM AND 0.655 INCHES MAXIMUM |
| CPRQ | RESET METHOD | MANUAL |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC AND 28.0 DC ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| ADAU | BODY HEIGHT | 1.770 INCHES MAXIMUM |
| TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 2000.0 AC AND 2000.0 DC ALL LOCATIONS |
| CPRX | ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
| AJEC | BOSS HEIGHT | 0.220 INCHES MINIMUM AND 0.280 INCHES MAXIMUM |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 9.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| ADAQ | BODY LENGTH | 2.000 INCHES NOMINAL |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCK RESISTANT AND VIBRATION RESISTANT AND HUMIDITY RESISTANT |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.