| Alternative NSN: 5925-01-392-9915 |
| Item Name: Circuit Breaker |
| CAGE Code : 0U583 , 81343 |
| NIIN: 013929915 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: sae international , society of automotive engineers inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| MS25244-PT15 | sae international | circuit breaker | Avl | |
| AS58091 | sae international | circuit breaker | Avl | |
| SAE-AS58091 | sae international | circuit breaker | Avl | |
| MS25244-PT15 | society of automotive engineers inc | circuit breaker | Avl | |
| SAE AS25244 | society of automotive engineers inc | circuit breaker | Avl | |
| AS58091 | society of automotive engineers inc | circuit breaker | Avl | |
| SAE AS58091 | society of automotive engineers inc | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | SINGLE POLE TYPE |
| ADAT | BODY WIDTH | 0.750 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 1.094 INCHES MAXIMUM |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 3500.0 AC AND 6000.0 DC SINGLE LOCATION |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
| ZZZK | SPECIFICATION/STANDARD DATA | 96906-MS25244 GOVERNMENT SPECIFICATION |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
| CPRQ | RESET METHOD | MANUAL |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
| CQJX | NOMINAL THREAD SIZE | 0.469 INCHES |
| FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE LOCATION |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 115.0 AC AND 28.0 DC SINGLE LOCATION |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SINGLE LOCATION |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| ABXD | BUSHING LENGTH | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.673 INCHES MINIMUM AND 0.735 INCHES MAXIMUM |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.840 INCHES MAXIMUM |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 15.0 AMPERES AC AND 15.0 AMPERES DC SINGLE LOCATION |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 15.000 MINIMUM AT 200 PCT AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
| FEAT | SPECIAL FEATURES | ITEM INCLUDES A MOUNTING BRACKET,AND EXTRA LONG TERMINALS |
| TEST | TEST DATA DOCUMENT | 81349-MIL-C-5809 SPECIFICATION INCLUDES ENGINEERING TYPE BULLETINS,BROCHURES,ETC.,THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT EXCLUDES COMMERCIAL CATALOGS,INDUSTRY DIRECTORIES,AND SIMILAR TRADE PUBLICATIONS,REFLECTIN |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB,SOLDER LUG |