| Alternative NSN: 5925-01-396-1123 |
| Item Name: Circuit Breaker |
| CAGE Code : 16236 , 74193 , 81541 |
| NIIN: 013961123 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: dla land and maritime , eaton corporation , sensata technologies inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 87057-018 | dla land and maritime | circuit breaker | Avl | |
| HM2-224-018 | eaton corporation | circuit breaker | Avl | |
| AP12-R-87057-018 | sensata technologies inc | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
| ABXD | BUSHING LENGTH | 0.380 INCHES MAXIMUM |
| ADAQ | BODY LENGTH | 1.562 INCHES MAXIMUM |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0.875 INCHES NOMINAL |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.780 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 2 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC AND 50.0 DC ALL LOCATIONS |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
| CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE ONE |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.500 MINIMUM AT 200 PCT AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
| CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 0.5 AC AND 0.5 DC |
| FREQ | FREQUENCY IN HERTZ | 400.0 ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE HOOK |
| ADAT | BODY WIDTH | 1.281 INCHES MAXIMUM |
| CPRQ | RESET METHOD | MANUAL |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.625 INCHES NOMINAL |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 300.0 AC AND 500.0 DC ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | MAGNETIC ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 ALL LOCATIONS |
| CRTK | SWITCH TERMINAL TYPE | TAB,SOLDER LUG |
| CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 120.0 AC AND 50.0 DC |
| THSD | THREAD SERIES DESIGNATOR | UNEF |
| AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE,DOUBLE THROW |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC AND 2.0 AMPERES DC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
| CPRX | ACTUATOR POSITION DESIGNATION | BETWEEN POLE ONE AND TWO |
| CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
| CQJX | NOMINAL THREAD SIZE | 0.375 INCHES |