| Alternative NSN: 5925-01-473-2947 |
| Item Name: Circuit Breaker |
| CAGE Code : 81541 |
| NIIN: 014732947 |
| FSC Name: 5925 Circuit Breakers |
| NCB Code: USA (01) |
| Manufacturers: sensata technologies inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| AP12-1R-72-252 | sensata technologies inc | circuit breaker | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| CPLM | Maximum Continuous Load Current Rating Per Pole | 2.5 AMPERES AC ALL LOCATIONS |
| FREQ | Frequency In Hertz | 400.0 ALL LOCATIONS |
| ABXD | Bushing Length | 9.7 MILLIMETERS MAXIMUM |
| CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS |
| CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
| CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
| AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING |
| AKPX | Pole Quantity | 2 |
| CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
| CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
| CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
| MRC | Decoded Requirement | Clear Text Reply |
| CPRX | Actuator Position Designation | BETWEEN POLE ONE AND TWO |
| CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
| ADTV | Case Material | METAL |
| CPRW | Actuator Function | TRIP-RESET |
| ADAT | Body Width | 32.5 MILLIMETERS MAXIMUM |
| THSD | Thread Series Designator | UNEF |
| AJWX | Mounting Surface To Terminal End Distance | 45.1 MILLIMETERS MAXIMUM |
| CQJX | Nominal Thread Size | 0.375 INCHES |
| ADAQ | Body Length | 39.7 MILLIMETERS MAXIMUM |
| AEBP | Center To Center Distance Between Terminals Parallel To Length | 22.2 MILLIMETERS NOMINAL |
| TTQY | Terminal Type And Quantity | 4 WIRE HOOK |
| AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
| AEBQ | Center To Center Distance Between Terminals Parallel To Width | 15.9 MILLIMETERS NOMINAL |
| CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
| CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.100 MAXIMUM AT 135 PCT ALL LOCATIONS |
| CMLP | Thread Quantity Per Inch | 32 |
| CPRQ | Reset Method | MANUAL |
| CPSM | Internal Trip Release Configuration | SERIES TRIP W/AUXILIARY LOAD TERMINAL ALL LOCATIONS |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.