| Alternative NSN: 5930-01-108-8528 |
| Item Name: Switch Pressure |
| CAGE Code : 5RQL2 , 90598 , 92578 , 53047 |
| NIIN: 011088528 |
| FSC Name: 5930 Switches |
| NCB Code: USA (01) |
| Manufacturers: drs environmental systems inc , engineered air systems inc , johnson controls inc , rheem manufacturing company |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| D21467 | drs environmental systems inc | switch pressure | Avl | |
| D21467 | engineered air systems inc | switch pressure | Avl | |
| 275AP10EM0DEL4512 | johnson controls inc | switch pressure | Avl | |
| 4512 | johnson controls inc | switch pressure | Avl | |
| P-28NA-14 | johnson controls inc | switch pressure | Avl | |
| P28NA6 | johnson controls inc | switch pressure | Avl | |
| D21467 | rheem manufacturing company | switch pressure | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | MOISTURE PROOF |
| ABHP | OVERALL LENGTH | 5.656 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 5.297 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 2.094 INCHES NOMINAL |
| ABTD | MOUNTING SLOT WIDTH | 0.375 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.250 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.203 INCHES NOMINAL |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.984 INCHES NOMINAL |
| AFDU | INTERMEDIATE HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.562 INCHES NOMINAL |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.000 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | 4120010802850 90598 |
| AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
| AXGY | MOUNTING METHOD | SLOT AND UNTHREADED HOLE AND THREADED HOLE |
| CBBL | FEATURES PROVIDED | CAPILLARY TUBE END SEAL CONNECTION |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION PARALLELOGRAM |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CSCF | TERMINAL TYPE | SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | 16.00 ACTUATION POINT NOMINAL POUND AND 11.00 DEACTUATION POINT NOMINAL POUND |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 24.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
| STYL | STYLE DESIGNATOR | RECTANGULAR |