| Alternative NSN: 5930-01-321-1894 |
| Item Name: Switch Thermostatic |
| CAGE Code : 19278 , 19857 |
| NIIN: 013211894 |
| FSC Name: 5930 Switches |
| NCB Code: USA (01) |
| Manufacturers: detroit switch inc , electric heater company the |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 222-10NH2-2223476 | detroit switch inc | switch thermostatic | Avl | |
| NH2-222-3476 | electric heater company the | switch thermostatic | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT |
| ABHP | OVERALL LENGTH | 5.188 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 5.687 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 2.812 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 2.750 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.281 INCHES NOMINAL |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 5.188 INCHES NOMINAL |
| AFDT | SHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.656 INCHES NOMINAL |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 3.281 INCHES NOMINAL |
| AKBY | TEMP SENSING ELEMENT TYPE | BULB |
| AWTN | OPERATING TEMP RATING | 245.0 DEG FAHRENHEIT MAXIMUM |
| AXGY | MOUNTING METHOD | BRACKET AND UNTHREADED HOLE |
| CBBL | FEATURES PROVIDED | ELECTRICAL ACCESS PORT |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CQYJ | MOUNTING FACILITY PATTERN | ISOSCELES TRIANGLE |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,SINGLE THROW,NORMALLY OPEN,MOMENTARY ACTION |
| CSCF | TERMINAL TYPE | SCREW |
| CTHF | CONTACT LOAD CURRENT RATING | 16.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 2.0 AMPERES INDUCTIVE LOAD EIGHTH VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 2.5 AMPERES INDUCTIVE LOAD SEVENTH VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 3.2 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 4.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 4.8 AMPERES INDUCTIVE LOAD SIXTH VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| CTHF | CONTACT LOAD CURRENT RATING | 9.6 AMPERES INDUCTIVE LOAD FIFTH VOLTAGE |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
| CTYM | CONTACT ADJUSTMENT RANGE | 140.00 TO 215.00 ACTUATION POINT DEGREES FAHRENHEIT AND 140.00 TO 215.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CTYS | CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 115.0 DC AT SEA LEVEL FIFTH VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 AC AT SEA LEVEL SECOND VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 230.0 DC AT SEA LEVEL SIXTH VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 AC AT SEA LEVEL THIRD VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 440.0 DC AT SEA LEVEL SEVENTH VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 AC AT SEA LEVEL FOURTH VOLTAGE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 550.0 DC AT SEA LEVEL EIGHTH VOLTAGE |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS |
| PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
| PRMT | PRECIOUS MATERIAL | SILVER |
| STYL | STYLE DESIGNATOR | RECTANGULAR |