| Alternative NSN: 5930-01-365-3652 |
| Item Name: Switch Thermostatic |
| CAGE Code : 94607 |
| NIIN: 013653652 |
| FSC Name: 5930 Switches |
| NCB Code: USA (01) |
| Manufacturers: amot controls corporation |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 8253A140AK195FR | amot controls corporation | switch thermostatic | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ABMK | OVERALL WIDTH | 1.063 INCHES NOMINAL |
| CQGB | CONTACT ACTION STIMULUS | INCREASE |
| CTHF | CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| CTYM | CONTACT ADJUSTMENT RANGE | 182.00 TO 211.00 ACTUATION POINT DEGREES FAHRENHEIT |
| ABHP | OVERALL LENGTH | 3.386 INCHES NOMINAL |
| AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| AXGY | MOUNTING METHOD | THREADED STUD |
| CSCF | TERMINAL TYPE | THREADED HOLE AND THREADED STUD |
| STYL | STYLE DESIGNATOR | RECTANGULAR |
| ABKW | OVERALL HEIGHT | 5.394 INCHES NOMINAL |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
| CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT POINTER WITH SCALE |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE30.0 DC AT SEA LEVEL SECOND VOLTAGE |
| MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |