| MRC | Criteria | Characteristic |
|---|---|---|
| ABHP | OVERALL LENGTH | 1.438 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 1.094 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 0.875 INCHES NOMINAL |
| ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
| APFR | CONTACT ARRANGEMENT | SINGLE POLE,SINGLE THROW,NORMALLY OPEN |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |
| CYCS | CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| CYCT | CONTACT MAXIMUM CURRENT RATING IN AMPS | 6.0 AC OR 3.0 DC |
| CYCU | HEATER VOLTAGE RATING IN VOLTS | 115.0 |
| CYCV | HEATER POWER RATING IN WATTS | 4.0 |
| CYCW | DELAY TIME IN SECONDS | 120.0 FIXED OPERATE NOMINAL |
| TTQY | TERMINAL TYPE AND QUANTITY | 7 WIRE HOOK |