| Alternative NSN: 5945-00-803-9535 |
| Item Name: Relay Electromagnet |
| CAGE Code : K0999 , 71482 , C1834 , D0080 , 56623 , 94696 , 58614 |
| NIIN: 008039535 |
| FSC Name: 5945 Relays and Solenoids |
| NCB Code: USA (00) |
| Manufacturers: bae systems inc , cp clare corp , kontron ag , leach international germany gmbh , microsemi corporation , se relays llc , tyco electronics corporation |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| RP7641G8 | bae systems inc | relay electromagnet | Avl | |
| RP7641G8TYPEF | cp clare corp | relay electromagnet | Avl | |
| RP7641G8 | cp clare corp | relay electromagnet | Avl | |
| 109319-1 | kontron ag | relay electromagnet | Avl | |
| RP7641G8 | leach international germany gmbh | relay electromagnet | Avl | |
| BR12-675A1-26V | microsemi corporation | relay electromagnet | Avl | |
| VR2C675D24 | se relays llc | relay electromagnet | Avl | |
| RP7641G8 | tyco electronics corporation | relay electromagnet | Avl | |
| RP7641G8TYPEF | tyco electronics corporation | relay electromagnet | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| ADTV | CASE MATERIAL | METAL |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AFRG | CONTACT MATERIAL | SILVER |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| APNP | DUTY TYPE | CONTINUOUS |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CBME | CUBIC MEASURE | 0.347 CUBIC INCHES |
| CRXH | TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
| PRMT | PRECIOUS MATERIAL | SILVER |
| ABHP | OVERALL LENGTH | 0.800 INCHES MAXIMUM |
| ABKW | OVERALL HEIGHT | 1.087 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 0.400 INCHES MAXIMUM |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKDX | WINDING QUANTITY | 1 |
| APCN | COIL QUANTITY | 1 |
| APNA | WINDING DC RESISTANCE RATING | 675.0 OHMS NOMINAL SINGLE WINDING |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
| PMLC | PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
| TTQY | TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |