| Alternative NSN: 5950-00-099-0091 |
| Item Name: Transformer Power |
| CAGE Code : 24429 |
| NIIN: 000990091 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (00) |
| Manufacturers: astec america inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 11254 | astec america inc | transformer power | Avl | |
| 40-11254-001 | astec america inc | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | 0.120 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 1.450 INCHES NOMINAL |
| ADAT | BODY WIDTH | 1.120 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 1.190 INCHES NOMINAL |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 60.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 8.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 8 TAB,SOLDER LUG |