Alternative NSN: 5950-00-116-3474 |
Item Name: Transformer Power |
CAGE Code : 17863 , 72964 |
NIIN: 001163474 |
FSG: 59 Electrical and Electronic Equipment Components |
FSC Name: 5950 Coils and Transformers |
NCB Code: USA (00) |
Manufacturers: litton systems inc , robert m hadley company inc |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
7117028-1 | litton systems inc | transformer power | Avl | |
16967 | robert m hadley company inc | transformer power | Avl |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 3.500 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.438 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1.875 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.630 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.151 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | TWO PHASE TO TWO PHASE SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.630 INCHES NOMINAL |
ADAU | BODY HEIGHT | 1.875 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE AND UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.3 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.7 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 199.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 27.60 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TURRET |