| Alternative NSN: 5950-00-168-4065 |
| Item Name: Transformer Power |
| CAGE Code : 88277 , 76301 , 19133 , 72964 |
| NIIN: 001684065 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (00) |
| Manufacturers: boeing company the , mcdonnell douglas corp , robert m hadley company inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 7669002-517 | boeing company the | transformer power | Avl | |
| 902598 | boeing company the | transformer power | Avl | |
| 902598 | mcdonnell douglas corp | transformer power | Avl | |
| 17234 | robert m hadley company inc | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.360 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.390 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.735 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.765 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTB | MOUNTING HOLE DIAMETER | 0.143 INCHES MINIMUM SINGLE GROUP AND 0.172 INCHES MAXIMUM SINGLE GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
| ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 1.250 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 3.000 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 3 SINGLE GROUP |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 250.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
| TEST | TEST DATA DOCUMENT | 19133-902598 DRAWING THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC. EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
| TTQY | TERMINAL TYPE AND QUANTITY | 7 THREADED STUD |