| Alternative NSN: 5950-00-645-0243 |
| Item Name: Transformer Power |
| CAGE Code : 97520 , 80089 , 82199 |
| NIIN: 006450243 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (00) |
| Manufacturers: basler electric company , emerson electric gmbh and co , rohde and schwarz inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 28636 | basler electric company | transformer power | Avl | |
| PD146 | emerson electric gmbh and co | transformer power | Avl | |
| 709P4 | emerson electric gmbh and co | transformer power | Avl | |
| DP14948 | rohde and schwarz inc | transformer power | Avl | |
| BP12962REVH | rohde and schwarz inc | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 3.562 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 4.250 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 3.375 INCHES NOMINAL |
| ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 1.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 2.0 AMPERES DC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 25.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 800.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 0.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 127.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 3.50 AC KILOVOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 4.50 AC KILOVOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.30 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 20 TAB,SOLDER LUG |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.