| Alternative NSN: 5950-01-051-8283 |
| Item Name: Transformer Power |
| CAGE Code : 28480 , 1LQK8 , 3Z577 , 17474 |
| NIIN: 010518283 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (01) |
| Manufacturers: hewlett-packard company , keysight technologies inc , onan corp , tranex inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 9100-3410 | hewlett-packard company | transformer power | Avl | |
| 9100-3410 | keysight technologies inc | transformer power | Avl | |
| 3-19700 | onan corp | transformer power | Avl | |
| 14-6631 | tranex inc | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABTB | MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 440.0 HERTZ MAXIMUM SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 3.000 INCHES NOMINAL |
| ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 4.250 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
| CWJS | WINDING OPERATING VOLTAGE | 100.00 AC VOLTS MINIMUM SINGLE COMPONENT 1ST PRIMARY AND 120.00 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 143.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 21.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 21.40 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 220.00 AC VOLTS MINIMUM SINGLE COMPONENT 2ND PRIMARY AND 250.00 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 8.80 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| FEAT | SPECIAL FEATURES | 2 PRIMARYS 6 SECONDARY WINDINGS |
| TTQY | TERMINAL TYPE AND QUANTITY | 20 WIRE LEAD |