| Alternative NSN: 5950-01-086-0041 |
| Item Name: Transformer Power |
| CAGE Code : 07187 , 15634 , 26543 |
| NIIN: 010860041 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (01) |
| Manufacturers: honeywell international inc , magnetika inc , wems electronics |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 4015349 | honeywell international inc | transformer power | Avl | |
| 4034344 | honeywell international inc | transformer power | Avl | |
| WE3030 | magnetika inc | transformer power | Avl | |
| WE3030 | wems electronics | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 3.700 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.428 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.448 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 1.665 INCHES MAXIMUM |
| ABTB | MOUNTING HOLE DIAMETER | 0.161 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-OPEN DELTA AND WYE-WYE |
| ADAT | BODY WIDTH | 2.580 INCHES MINIMUM AND 2.680 INCHES MAXIMUM |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 7 SECONDARY SINGLE COMPONENT |
| CRBZ | WINDING OPERATING CURRENT | 130.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 390.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 201.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 36.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 77.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 31 WIRE LEAD |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.