| Alternative NSN: 5950-01-147-3532 |
| Item Name: Transformer Power |
| CAGE Code : 54519 , 19623 , A486G |
| NIIN: 011473532 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (01) |
| Manufacturers: dytek laboratories , ge aviation systems ltd , nimikkeistokeskus ncb finland |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 3-400003 | dytek laboratories | transformer power | Avl | |
| 006465 | ge aviation systems ltd | transformer power | Avl | |
| 10132853 | nimikkeistokeskus ncb finland | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABHP | OVERALL LENGTH | 2.750 INCHES MAXIMUM |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.281 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ABKW | OVERALL HEIGHT | 2.969 INCHES MAXIMUM |
| ABMK | OVERALL WIDTH | 2.250 INCHES MAXIMUM |
| ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
| AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
| CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
| CRBZ | WINDING OPERATING CURRENT | 1.5 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 105.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 127.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.18 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.18 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 6.18 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
| FEAT | SPECIAL FEATURES | 1 PRIMARY WINDING 6 SECONDARY WINDINGS |
| THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
| TTQY | TERMINAL TYPE AND QUANTITY | 39 TAB,SOLDER LUG |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.