Alternative NSN: 5950-01-258-3994 |
Item Name: Transformer Pulse |
CAGE Code : 0B3R2 , 3B150 |
NIIN: 012583994 |
FSC Name: 5950 Coils and Transformers |
NCB Code: USA (01) |
Manufacturers: albert langan , raytheon company |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
807054 | albert langan | transformer pulse | Avl | |
807054 | raytheon company | transformer pulse | Avl |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.125 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.105 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 5.135 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.985 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 3.015 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.250 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | 0.298 INCHES MINIMUM SINGLE GROUP AND 0.307 INCHES MAXIMUM SINGLE GROUP |
ACYV | INDUCTANCE RATING | 10.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
ACZN | PULSE REPETITION RATE | 10.0 HERTZ SINGLE COMPONENT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 150.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 23.300 SINGLE COMPONENT SINGLE PRIMARY |
TTQY | TERMINAL TYPE AND QUANTITY | 1 STANDOFF,THREADED STUD AND 3 THREADED STUD |