| Alternative NSN: 5950-01-273-2923 |
| Item Name: Transformer Power |
| CAGE Code : 31515 , 34511 |
| NIIN: 012732923 |
| FSC Name: 5950 Coils and Transformers |
| NCB Code: USA (01) |
| Manufacturers: f and r enterprises , fluke biomedical corporation |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| 11N21 | f and r enterprises | transformer power | Avl | |
| 100833 | fluke biomedical corporation | transformer power | Avl | |
| 12010012 | fluke biomedical corporation | transformer power | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABTB | MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SINGLE GROUP |
| ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
| ADAQ | BODY LENGTH | 2.250 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 1.922 INCHES MINIMUM AND 1.954 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.359 INCHES MINIMUM AND 2.391 INCHES MAXIMUM |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.359 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.391 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AKNA | INCLOSURE TYPE | OPEN |
| AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
| BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| CBBL | FEATURES PROVIDED | COLOR CODED LEAD |
| CRBZ | WINDING OPERATING CURRENT | 3.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| CRBZ | WINDING OPERATING CURRENT | 550.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CRMJ | WINDING POWER RATING | 0.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| CRMJ | WINDING POWER RATING | 9.9 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |
| CWJS | WINDING OPERATING VOLTAGE | 18.00 DC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
| CWJS | WINDING OPERATING VOLTAGE | 230.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 9 WIRE LEAD |