| Alternative NSN: 6130-01-384-9693 |
| Item Name: Power Supply |
| CAGE Code : 25965 |
| NIIN: 013849693 |
| FSC Name: 6130 Converters Electrical Non Rotating |
| NCB Code: USA (01) |
| Manufacturers: ametek programmable power inc |
|
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
|---|---|---|---|---|
| AT8-07-01-02-01-2098 | ametek programmable power inc | power supply | Avl |
| MRC | Criteria | Characteristic |
|---|---|---|
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 230.0 AC VOLTS NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 4TH POWER OUTPUT AND 40.0 DC VOLTS MAXIMUM 4TH POWER OUTPUT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 5TH POWER OUTPUT AND 32.0 DC VOLTS MAXIMUM 5TH POWER OUTPUT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 6TH POWER OUTPUT AND 20.0 DC VOLTS MAXIMUM 6TH POWER OUTPUT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 8TH POWER OUTPUT AND 7.0 DC VOLTS MAXIMUM 8TH POWER OUTPUT |
| CWGH | OUTPUT CURRENT RATING | 6.0 DC AMPERES MINIMUM 6TH POWER OUTPUT AND 10.0 DC AMPERES MAXIMUM 6TH POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 6TH POWER OUTPUT |
| CWHQ | INPUT CONNECTION TYPE | CONNECTOR,PLUG 2ND ALTERNATE OPERATING POWER RQMT |
| CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
| CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
| ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 3RD POWER OUTPUT AND 80.0 DC VOLTS MAXIMUM 3RD POWER OUTPUT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 7TH POWER OUTPUT AND 10.0 DC VOLTS MAXIMUM 7TH POWER OUTPUT |
| AYNH | OPERATING AMBIENT TEMP RANGE | 0.1 TO 50.0 DEG CELSIUS |
| CWGH | OUTPUT CURRENT RATING | 12.0 DC AMPERES NOMINAL 7TH POWER OUTPUT |
| CWGH | OUTPUT CURRENT RATING | 15.0 DC AMPERES NOMINAL 8TH POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 4TH POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 7TH POWER OUTPUT |
| CWHM | INPUT CURRENT RATING | 0.2 AC AMPERES MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 2.4 AC AMPERES MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| CWHM | INPUT CURRENT RATING | 0.5 AC AMPERES MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 4.8 AC AMPERES MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| APNX | INPUT VOLTAGE RATING | 115.0 AC VOLTS NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 2ND POWER OUTPUT AND 160.0 DC VOLTS MAXIMUM 2ND POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
| CBBL | FEATURES PROVIDED | ON-OFF SWITCH-INDICATOR AND PROGRAMMABLE AND OVER VOLTAGE PROTECTOR |
| CWGH | OUTPUT CURRENT RATING | 0.7 DC AMPERES MINIMUM 2ND POWER OUTPUT AND 1.2 DC AMPERES MAXIMUM 2ND POWER OUTPUT |
| CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES MINIMUM 4TH POWER OUTPUT AND 5.0 DC AMPERES MAXIMUM 4TH POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 3RD POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 7TH POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 8TH POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 5TH POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 8TH POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 4TH POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 5TH POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 8TH POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 4TH POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 5TH POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 6TH POWER OUTPUT |
| CWHF | OUTPUT CONNECTION QUANTITY | 1 7TH POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
| CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 6TH POWER OUTPUT |
| CWHQ | INPUT CONNECTION TYPE | CONNECTOR,PLUG 1ST ALTERNATE OPERATING POWER RQMT |
| CWKG | VENTILATION DESIGN TYPE | INTERNAL BLOWER AND DUAL FAN |
| ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
| ABKW | OVERALL HEIGHT | 6.250 INCHES NOMINAL |
| ABMK | OVERALL WIDTH | 21.000 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | LANTIRN DEPOT SET |
| APPA | OUTPUT VOLTAGE RATING | 0.0 DC VOLTS MINIMUM 1ST POWER OUTPUT AND 320.0 DC VOLTS MAXIMUM 1ST POWER OUTPUT |
| APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 440.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
| CWGH | OUTPUT CURRENT RATING | 0.3 DC AMPERES MINIMUM 1ST POWER OUTPUT AND 0.6 DC AMPERES MAXIMUM 1ST POWER OUTPUT |
| CWGH | OUTPUT CURRENT RATING | 1.5 DC AMPERES MINIMUM 3RD POWER OUTPUT AND 2.5 DC AMPERES MAXIMUM 3RD POWER OUTPUT |
| CWGH | OUTPUT CURRENT RATING | 3.7 DC AMPERES MINIMUM 5TH POWER OUTPUT AND 6.2 DC AMPERES MAXIMUM 5TH POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 1ST POWER OUTPUT |
| CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 2ND POWER OUTPUT |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.