Upload| Part Number : BQ3-B100 | Alternate P/N : BQ3B100 | NSN : 5925004210759 |
|
|
Manufacturer : Spd Electrical Systems Inc | CAGE Code : 30086 |
| FSC Details : 5925 Circuit Breakers | NIIN : 004210759 | INC Code : 00136 |
| Country : USA | NCB Code : 00 |
Thank You for Submitting Your RFQ for Part Number BQ3-B100 by Spd Electrical Systems Inc
We always put our customers’ needs first, and we are always just a click or call away from assisting you throughout the purchasing process whenever you need it. Please do not hesitate to call our toll-free number +1-714-705-4780 for any inquiries about part number BQ3-B100, or send us an email listing your needs, and we will get back to you as soon as possible. Whatever your requirements may be, we will not rest until we have fulfilled all your operational needs with highly competitive options.
| NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
|---|---|---|---|---|---|---|
| 5925-00-421-0759 Item PartTypeName: CIRCUIT BREAKER | 5925 | 004210759 | 0 | P | ||
| CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
| U | A | |||||
| Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
| 10937537 | 2 | 1 | 3 |
| MRC | Criteria | Characteristic |
|---|---|---|
| AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
| ADAQ | BODY LENGTH | 3.735 INCHES MINIMUM AND 3.765 INCHES MAXIMUM |
| ADAT | BODY WIDTH | 2.985 INCHES MINIMUM AND 3.015 INCHES MAXIMUM |
| ADAU | BODY HEIGHT | 2.485 INCHES MINIMUM AND 2.515 INCHES MAXIMUM |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.985 INCHES MINIMUM AND 1.015 INCHES MAXIMUM |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AJEC | BOSS HEIGHT | 0.172 INCHES MINIMUM AND 0.202 INCHES MAXIMUM |
| AKPX | POLE QUANTITY | 3 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 CLIP |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 100.0 AMPERES AC ALL LOCATIONS |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240.0 AC ALL LOCATIONS |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 10000.0 AC ALL LOCATIONS |
| CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
| CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
| CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 3 TOGGLE |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE,TWO,AND THREE LINKED |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | 50.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
| CWJK | CASE MATERIAL | PLASTIC |
| FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
| TTQY | TERMINAL TYPE AND QUANTITY | 3 COMPRESSION AND 3 TAB W/SCREW |