MRC | Criteria | Characteristic |
---|
ABHP | OVERALL LENGTH | 13.250 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.125 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 6.875 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.500 INCHES NOMINAL |
ADAQ | BODY LENGTH | 12.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 6.875 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 12.875 INCHES NOMINAL |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 5.0 TO 25.0 |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 6.000 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | 0.0 TO 70.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 3.0 OHMS BLANK |
AHAS | LOAD IMPEDANCE PER FUNCTION | 3.0 OHMS BLANK |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 10.0 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 SLOT |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 TAB,SOLDER LUG GROUND 3RD FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 THREADED STUD OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQRG | BODY MATERIAL | METAL |
CRST | BODY SURFACE TREATMENT | TIN |
CTJS | UNPACKAGED UNIT WEIGHT | 12.000 POUNDS NOMINAL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ADJACENT SURFACES |