Alternative NSN: 5950-01-186-0212 |
Item Name: Transformer Power |
CAGE Code : 72149 , 25230 , 95970 , 10109 |
NIIN: 011860212 |
FSG: 59 Electrical and Electronic Equipment Components |
FSC Name: 5950 Coils and Transformers |
NCB Code: USA (01) |
Manufacturers: electronic transformer corp , magnetek inc , mte corp , power paragon inc |
Part No Part No
|
Manufacturer |
Item Name Item Name
|
QTY QTY
|
RFQ RFQ
|
---|---|---|---|---|
C18900 | electronic transformer corp | transformer power | Avl | |
11G006968-001 | magnetek inc | transformer power | Avl | |
11G006968-001 | mte corp | transformer power | Avl | |
920-06968-001 | power paragon inc | transformer power | Avl |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.200 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.270 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.060 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.380 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTD | MOUNTING SLOT WIDTH | 0.312 INCHES NOMINAL SINGLE GROUP |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 7.500 INCHES MAXIMUM |
ADAT | BODY WIDTH | 6.120 INCHES NOMINAL |
ADAU | BODY HEIGHT | 6.000 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | COUNTERMEASURES SYSTEMS. AUSTIN SHIP CLASS LPD-4 AMPHIBIOUS TRANSPORT DOCKS. ARLEIGH BURKE CLASS DDG. |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 9.0 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
CWJS | WINDING OPERATING VOLTAGE | 110.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 440.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
TTQY | TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG |
Before You Go, You Should Consider Looking at Our NSN Parts Catalog. and Remember, ASAP Sourcing Solutions Has Some of the Fastest and Most Competitive Quotes On the Market.
Request for Quote